PE stamped structural plans

Licensed Professional Engineers · PE stamp & permit plans in all 50 states+1 (520) 502-9169  ·  contactpedrawings@gmail.com  ·  Mon–Sat 8am–8pm ET
STRUCTURAL · SHEET SERIES S

PE Stamped Structural Plans & Sealed Structural Calculations

Beam sizing, foundations, framing, lateral design and repairs — drafted, calculated to code and sealed by a Professional Engineer licensed in your state.

Get a free quoteStart live chat

PROJECTPE DRAWINGS
DISCIPLINEStructural engineering
CODESIBC · IRC · ASCE 7
NDS · ACI · AISC · TMS
MATERIALSWood · Steel
Concrete · Masonry
INCLUDESSealed calculation
package
LICENSED
PROFESSIONAL
ENGINEER
SEAL
Send a photo of the wall, beam or footing
Drop it into live chat and an engineer will tell you what the permit will require before you spend anything.

Send it in chat

SCOPE OF WORK

What our PE stamped structural drawings cover

Structural work is where building departments apply the most scrutiny, because it is where failure is least forgiving. Every structural sheet we issue is backed by a calculation set that shows the load path from roof to soil.

  • Load-bearing wall removal — beam and column sizing, temporary shoring notes, bearing and foundation checks
  • Foundations — spread footings, strip footings, piers, slabs, underpinning, frost depth compliance
  • Floor and roof framing — joists, rafters, trusses, headers, girders, LVL and PSL specification
  • Lateral systems — shear walls, hold-downs, bracing, wind and seismic force resistance per ASCE 7
  • Decks, porches, balconies — ledger attachment, guard loads, post and footing design
  • Retaining walls — overturning, sliding and bearing stability, reinforcement schedules
  • Steel structures — mezzanines, platforms, canopies, moment and shear connection design
  • Repairs and reinforcement — termite and rot damage, cracked slabs, sistering, post-tension repair
  • Additions and second storeys — verifying the existing structure can carry the new loads

Inside the sealed calculation package

  • Design criteria: code edition, wind speed, exposure, seismic category, snow and live loads
  • Tributary areas and load takedown for each member
  • Member-by-member checks with demand-capacity ratios
  • Connection, bearing and anchorage checks
  • Foundation sizing against the assumed or reported soil bearing capacity
  • Assumptions and field-verification notes stated plainly

Get a structural quote

ROOF RAFTERS @ 16″ O.C.DBL. TOP PLATE / BEAM2×6 STUD WALL @ 16″ O.C.FLOOR JOIST + RIM BOARDSILL PLATE + ANCHOR BOLTSFOUNDATION WALLSPREAD FOOTINGBELOW FROST DEPTHTYPICAL WALL SECTION — SHEET S-201

Typical wall section · sheet S-201
HOW WE DRAW IT

Details an inspector can actually build from

Every structural sheet shows the load path in section: footing size and depth, foundation wall, anchor bolts, sill, joists, studs, top plate and rafters — with the hardware called out where it matters.

Get a structural quote

SHEET LIST

A typical residential structural permit set

Sheet Content Why the reviewer wants it
S-001 General structural notes, design criteria, material specifications Proves the design basis matches the adopted code edition
S-101 Foundation plan with footing sizes, reinforcement and details Confirms new loads reach the soil safely
S-102 Floor framing plan with member sizes and beam schedule Shows every span, header and point load
S-103 Roof framing plan, bracing and connection layout Demonstrates uplift and lateral resistance
S-201 Sections and typical details, hardware and fastener schedule Tells the inspector exactly what to look for in the field
SC-01+ Sealed structural calculations Backs up every number printed on the sheets
Questions before you order?
Live chat connects you straight to an engineer who can confirm the sheets, the code sections and the price for your job.

Chat with an engineer now

FAQ

Frequently asked questions

How much does a PE stamped structural drawing cost?

A single beam or wall-removal item is the least expensive scope; a full framing and foundation package for an addition costs more because more members must be designed and checked. Every quote is fixed and given before work starts.

Do you need a site visit for structural work?

Usually not. Clear photographs, dimensions and a description of what is above and below the area are normally enough for residential scopes. When a condition cannot be determined remotely, we state the field-verification requirement directly on the drawings so the inspector knows what must be confirmed on site.

Can you size a beam for removing a load-bearing wall?

Yes — that is one of our most common requests. We calculate the tributary load, size the beam and its posts, check the bearing points down to the foundation, and issue either a sealed letter or a stamped structural sheet, depending on what your building department requires.

Which structural codes do you design to?

IBC and IRC as adopted by your jurisdiction, with ASCE 7 for loads, NDS for wood, AISC for steel, ACI for concrete and TMS for masonry — plus state amendments such as the Florida Building Code or California Building Code.

Do you provide stamped structural calculations as well as drawings?

Yes. Sealed calculations are included whenever the scope requires them, and most jurisdictions require them for anything beyond a simple letter.

FREE QUOTE · NO OBLIGATION

Request your free fixed quote

Send the address and the scope. You get a fixed price, a delivery date and the exact sheet list your building department expects — usually the same business day.

Quote request form

Attach photos, a sketch or your plan-review comments — whatever you have is enough to start.


Or skip the form entirely

Live chat reaches an engineer directly, and you can send images straight into the chat window. It is the fastest way to find out what your permit needs.

Start live chat

NEXT STEP

Need a beam sized or a wall opened up?

Send the span, what it carries and a couple of photos. Most structural letters are quoted within the hour and delivered within two business days.

Request my free quoteChat with an engineer

PE Drawings — PE stamped permit drawings, structural calculations and engineering letters for residential and commercial projects across the United States. Every set is reviewed and sealed by a Professional Engineer licensed in the project’s state.

© 2026 PE Drawings. All rights reserved.  |  Contact  |  FAQ

Scroll to Top